Teleconsultation Offline teleconsultationWith E-School you get a powerful tool to help you in your teaching duties.This is another function that virtual microscopy has compared to traditional microscopy.In routine practice, different results can be obtained using different stainings.Tissue microarrays (TMA) represent a fairly new invention in routine pathology, a solution you can use effectively only with virtual microscopy.Sometimes viewing a specimen in two dimensions is not enough.With fluorescent microscopy a whole new way is opened in the diagnostic process.Virtual microscopy is based upon digital data.


 


Rommedica


 

 

Privacy policy   
 
 

3DHISTECH Ltd

1.15. Release of the Pannoramic Scanner Software


Better image quality 

Digital slides scanned with the 1.15 software are sharper using a 3CCD camera and have better focus. (available only for 3CCD Hitachi and CIS camera)

New 3 CCD camera

The CIS 3 CCD camera with 2 MegaPixels for each color provides maximum resolution, lower noise and higher framerate than our previous 3 CCD camera. 

Interpolated focus in brightfield

Before scanning, the software measures the focus at multiple reference points over the sample. Based on these focus reference points, the software creates a focus map which will be used during scanning. This new focus algorithm provides a more  stable focusing quality and faster scanning compared to the previous method. 

New focusing algorithm

Ensures the optimum focus for the human eye. 3DHISTECH won the 40x image quality contest on the 1st European Scanner Contest by using this algorithm.

 

Fluorescence developments  

 

New camera for fluorescence

Support for a new high end monochrome camera PCO.edge featuring a high resolution, high framerate scientific CMOS chip, 16 bit image recording and extreme sensitivity with lower noise level. 

Lumencor light source

A new fluorescence light source is integrated into the system, which features six switchable channels, a lifetime of 10.000+ hours and higher power than a 120W metal halide short arc lamps. The channel switching takes only 200µs. Combined with a multi-band filter, Lumencor enables perfect co-localization and faster scanning of fluorescent slides. The new fluorescence camera can control the light source to turn the channels on and off for the exact exposure time the camera needs, thus eliminating unnecessary bleaching of the sample.


Z-STACK function in brightfield and fluoresence

With Z-stack the scanner saves multiple focus layers into the digital slide. Focusing is now possible in the Pannoramic Viewer just like using an optical microscope.


Scan to Server

Now it is possible to scan directly to the CaseCenter with the use of the Scan to Server functionality. The slides are instantly available in CaseCenter from anywhere in the world as soon as the slides are scanned in.


64-bit Windows 7

Thanks to the 64 bit operating system we can utilize larger amount of memory, the scanner program operates faster and more reliably. Starting from the 1.15. software version the scanner program runs only on 64 bit Windows 7 operating system.


Support for Pannoramic 250 Flash with new features

Our latest scanner has many new features for high speed and high quality in brightfield and fluorescence scanning!

For more details please visit this link!